ZXDP08 T601 Intelligent Busbar Trunking System

The whole design of the ZXDP08 T601 (V2.0R01) intelligent busbar adopts the modular design, that is, the standard components are overlapped to form the intelligent busbar products of the required scale. This product consists of four parts: Feeder unit, busbar trunking units, tap-off unit, and controller. The Feeder Unit includes the box, lightning protection, lightning protection micro-break, input plastic case, meter, monitoring board, internal copper bar, and connection cable. Busbar trunking units include the shell, copper busbar, connectors, bending parts, suspension parts (mounting brackets), socket components, and end cover plates. The tap-off box includes the box, pin connectors, MCB-breakers, industrial connectors, monitoring boards, and internal wiring materials. The main control box includes the box, monitoring board, LCD screen, and internal wiring materials.

Reliability

  • Comprehensive protection for system power supply, long‑service‑life.

 

Fast

  • Modular design, building‑block assembly.

 

Flexible

  • Flexible and diverse configurations for easy capacity expansion.

 

Intelligent

  • Real‑time monitoring, seamless integration with iDCIM.

Technical Specifications

ZXDP08 T601 Intelligent Busbar Trunking System Product Parameters
Solution Landscape ZXDP08 T601T(V2.0R01 AC)
ZXDP08 T601B(V2.0R01 DC)
Capacity Level ZXDP08 T601T(250A、400A、630A)
ZXDP08 T601B(250A、400A、630A、800A)
Composition AC/DC feeder box, busbar trunking units, tap-off box, monitoring box, and elbows
Tap-off box capacity 16~63A Optional
Busbar slot shell Aluminum alloy
Busbar slot shell Aluminum alloy
Socket Fixed
Lightning Protection Level Level C
Seismic test Level 9 Seismic
Key node temperature measurement Optional
Rated insulation voltage 1000V
Protection Level IP54 (without Feeder Unit and Tap-off Unit) IP44 (with Feeder Unit and Tap-off Unit)
Monitoring Screen 10 'touchscreen
Monitoring Parameters ZXDP08 T601T
Phase voltage, line voltage, phase current, line current, frequency, active power, reactive power, apparent power, power factor, active power degree, reactive power degree, harmonic content, temperature, switch status, lightning protection switch status, switch action alarm, and lightning protection fault alarm
ZXDP08 T601B