KU5200 V2 Disk Array

  • ZXCLOUD KU5200 V2 storage system is a high-end unified storage product that provides secure, reliable, and high-performance storage services to enterprise-level applications. With its industry leading hardware specifications, high-density interface design, advanced virtualization software concept of ZXCLOUD KingStor storage operation system, and complete value-added storage functions, KU5200 V2 can meet enterprise customers’ various storage requirements including storage capacity, IO performance, data security, service continuity, etc. It can be used with wide variety of applications such as medium/large-size database, high-performance computing, multimedia video data storage, file service, Internet application, backup, and disaster tolerance.  

    1. High Performance and Easy Expansion

    ■       High-performance multi-core processors used for controllers.

    ■       Up to 1.5TB DRAM data cache can be configured per controller enclosure.

    ■       High-density disk drawer within the 3U controller enclosure provides 42-Bays, in which 6 Bays are compatible with NVMe and SAS.

    ■       Up to 16 high-density IO interface cards, with up to 48* 1Gb iSCSI, 48* 10Gb iSCSI, 48* 16Gb FC, 48* 32Gb FC, 48* 1Gb NAS, 48* 10Gb NAS, and 24* 25Gb iSCSI host port  can be supported. Various application requirements can be fully met with such excellent connection capability. 

    ■       With up to 28 HD-miniSAS back-end interfaces, 2058* hard disks can be added into one system. 8192 hosts can simultaneously connect to 8192 LUNs exported by one system.  High-end large-capacity storage requirement can be easily met with these capacities. 

    ■        Higher performance and more cost-efficiency storage can be achieved with the Auto-tier function, which migrating data automatically between different types of disk(NVMe SSD、 SAS SSD、10K SAS HDD、7.2K NL_SAS HDD)  according their access frequency;

    ■       3rd Party storage virtualization function can be used to integrate external storage resources, to achieve heterogeneous unified management, data migration and data redundancy backup for other disk arrays.

    ■       With KU5200 V2’s scale-out architecture, linear growth of performance and capacity can be achieved by adding more controller enclosures. Up to 16 enclosures can be connected with high-speed matrix in one system.

    2. Highly Available and Reliable

    ■       Dual controllers work in ACTIVE-ACTIVE mode; fault part is isolated automatically; no single-point failure will cause service interruption.

    ■       Dual-storage cluster can be used as storage high availability or sotrage disaster recovery solutions. With its seamless fault switchover between two clustered storage system, RPO≈0/ RTO≈0 can be achieved.

    ■       All RAID levels such as RAID0, RAID1, RAID3, RAID5, RAID6, RAID10, RAID-TR and RAID50 can be supported , to meet different  data availability requirements . 

    ■       ZTE’s EEP virtualization technology can provide higher concurrent access capability than that of the traditional RAID and realize higher reliability and faster data reconstruction at the same time. 

    ■       Many advanced data management functions, such as Snapshot, Volume Clone (local and remote copy), Volume Migration, Active-Active Cluster, 3rd Storage Virtualization, Thin Provision, Auto Tier, SSD Cache, Virtual Clone, Real Clone, Disk Roaming, Synchronous/Asynchronous Remote Mirror, Load Balance, Host Multi-Path, BE Multi-Path,  Partial Reconstruction,  Disk Safe Analysis, Smart MAID, Cloud Backup and Data Destroy,  are support by KingStor storage operation system, provide users with a full range means for data protection;

    ■        With smart global Hot Spare technology, Hot Spare disks can be placed anywhere in system. Reconstruction can be cross-shelf and use any proper Hot Spare disk. 

    ■       With all hardware modular(e.g. Power, FAN, BBU, Interfaces) designed at least 1+1 redundancy, advanced C2F(Copy to Flash) power failure data protection technology, 99.999% system availability can be achieved.

    3. Customizable

    ■       As KU5200 V2 storage system, including its software and hardware, is developed, produced and tested by ZTE, we can provide highly flexible customization capability for some customers.

    4. Easy to O&M

    ■       Standard remote O&M access: Main industrial standard management interfaces such as SNMP, SMI-S and SwordFish are supported. By these interfaces, system can be O&M remotely.

    ■       Abundant management methods:  WUI,  CLI, and CAPI library management can be used for various system management tasks; Managers or management applications can access by IPv4 and IPv6 dual-stack at the same time. 

    ■       Rapid fault diagnosis: Hard disk SMART function and real-time software and hardware failure detection are implemented; and various alarm functions such as LED light and email notification are provided, to ensure that equipment fault information cannot be neglected or missed.

    ■       Comprehensive monitoring: Rich real-time and history io statistic data is provided to help users keeping track of system working status and resource usage; Hardware information such as environment temperature, power, and fans can be monitored remotely in real time to help user analysis system health status. 

    ■       Convenient maintenance: All controller, power modular, fan and hard disk can be hot-swapped;  types of disks can roam and mixed insert within system. Hardware maintenance becomes much simpler.

    5. Green, Energy Saving, and Environment Protection

    ■       Smart disk hibernating technology(Smart MAID) can reduce power and extend disks’ life.

    ■       Intelligent FAN speed control helps achieve low power consumption and low noise.

    ■       CPU intelligent frequency control function adjusts the working frequency based load level.

    ■       Green and harmless: lead-free and environmental friendly manufacture process.

          6. Technical Specifications (Dual-Controller Node)

    Features

    KU5200 V2

    Hardware

    Processor

    The latest high-performance multi-core processor

    Cache

    1.5TB

    Interface

    Supports 48* 1Gb iSCSI, 48* 10Gb iSCSI, 48* 16Gb FC, 48* 32Gb FC, 48* 1Gb  NAS, 48* 10Gb  NAS, 24* 25Gb  iSCSI, 28* 48Gb HD-miniSAS

    Number of local hard disks

    42 (6 bays are compatible with NVMe and SAS)

    Maximum  number of hard disks

    2058

    Specifications of hard disks

    2.5” 10K rpm SAS HDD: 300GB, 600GB, 900GB, 1.2TB, 1.8TB, 2.4TB

    2.5” 15K rpm SAS HDD: 300GB, 600GB

    3.5” 7.2 K rpm NLSAS HDD:  2TB, 4TB, 6TB, 8TB, 10TB

    2.5” SATA SSD: 480GB, 960GB, 1.92TB, 3.84TB

    2.5” SAS SSD: 400GB, 800GB, 960GB, 1.6TB, 1.92TB, 3.84TB, 7.68TB

    2.5” NVMe SSD: 1.6TB

    Power-down protection mode

    C2F permanent data power-down protection technology

    Software

    RAID support

    0, 1, 3, 5, 6, 10, 50, EEP,RAID-TR

    Number of supported LUN

    8192

    Number of connected host

    8192

    Number of single-roll snapshot

    1024

    Total number of snapshot

    4096

    Total number of copy

    2048

    Other features

    EEP, Snapshot, Volume Copy (local and remote copy), Volume Migration,  Active-Active Cluster, 3rd Storage Virtualization, Thin Provision, Auto Tier, SSD Cache, Virtual Clone, Real Clone, Disk Roaming, Synchronous/Asynchronous Remote Mirror, Load Balance, Host Multi-Path, BE Multi-Path,  Partial Reconstruction, Disk Safe Analysis, Smart MAID, and Data Destroy,etc.

    Manageability

    System management

    Supports WEB interface management

    Supports RS-232C serial port character terminal management 

    Supports command line menu and in-batches script mode configuration management 

    Supports SNMP, SMI-S, and  SwordFish protocol management interfaces

    Supports calling private CAPI 

    Support VMware VASA/VVOL/VAAI, OpenStack Cinder and other virtualization platform storage interfaces

    Reliability

    Fan

    N+1 redundancy, hot swap, intelligent speed control

    Power

    1+1 redundancy, hot swap

    Hard disk

    Multiple kinds of local and global Hot Spares

    Reliability index

    Availability is not less than 99.999%

    Host Compatibility

    OS supported

    Windows Server 2008 Enterprise/Standard x64 Edition SP1/SP2/R2

    Windows Server 2008/2008 R2 Datacenter x64 Edition SP1/SP2/R2                                       

    Windows Server 2012 Standard x64 Edition

    Windows Server 2012 R2 Datacenter x64 Edition SP1/SP2

    Red Hat Enterprise Linux 5 Update4/5/6/7/8/9/10/11 for x86_64

    Red Hat Enterprise Linux 6/Update1/2/3/4/5/6/7/8/9 for x86_64

    Red Hat Enterprise Linux 7/7.1/7.2/7.3  for x86_64

    CentOS 6.2/6.3/6.4/6.5/6.6/6.7/6.8 for x86_64

    CentOS 7/7.1/7.2/7.3 for x86_64

    SUSE Linux Enterprise Server 9 SP2/3/4 for i586

    SUSE Linux Enterprise Server 10/11 SP1/SP2/SP3 for x86_64

    SUSE Linux Enterprise Server 12 SP1 for x86_64

    Kylin 3.0 for x86_64

    Kylin 3.2 for x86_64

    Kylin 6.0 for x86_64

    ZXVEServerV1/V2/V3/V4  for x86_64

    NewStart CGSL V3/V4/V5 for x86_64

    Oracle Solaris 10/11 for x86_64

    Oracle Solaris 10/11 for SPARC (partly compatible)

    AIX 5.2 (MPIO FC SAN support)

    AIX 5.3 (MPIO FC SAN support)

    AIX 6.1 (MPIO FC SAN support)

    Virtualization platform:

    VMware ESXi 5.5/5.5 U1/U2/U3

    VMware ESXi 6.0/6.0 U1/U2

    VMware ESXi 6.5

    Hyper-V

    OpenStack

    Physical Features

    Power

    2* 1200W platinum  AC power module: 100~240V self-adaptive standard AC input or 240 HVDC input

    Environmental requirements

    Long-term working temperature: +5 °C ~ +35 °C

    Short-term working temperature: +0 ºC ~ +40ºC

    Storage temperature: -40 °C ~ +70 °C

    Relative humidity: working environment 20% - 80%, and non-working environment 10% - 95%

    Altitude: 10,000 feet

    Power consumption

    KU5200 V2 (3U control shelf) fully configured with 2.5” disks: 1000W

    KJ2024 V2 (2U disk shelf) fully configured with 2.5” disks: 240W

    KJ4024 (4U disk shelf) fully configured with 3.5” disks: 300W

    Size

    KU5200 V2 (3U control shelf) : 482.6(W) x 132.5(H) x 795(D)(mm)

    KJ2024 V2 (2U disk shelf): 482.6 (W) x 86.1(H) x 503(D)(mm)

    KJ4024 (4U disk shelf): 482.6 (W) x 176.2(H) x 590(D)(mm)

    Weight

    KU5200 V2 (3U control shelf): 48.8kg±5% 

    KJ2024 V2 (2U disk shelf): 18.2kg±5% 

    KJ4024 (4U disk shelf): 34.7kg±5%   

    Note: no hard disk

    Certificate

    FCC, CE, CB, RoHS, CCC, VMware, Openstack Cinder, FalconStor  VTL, software copyright certificates


Click:3266